High-Voltage Limit-Current Fuse For Protection Of Voltage Transformer

High-Voltage Limit-Current Fuse For Protection Of Voltage Transformer

This product can be used in indoor system of Ac50Hz and rated voltage of 3.6-40.5KV to protect the voltage mutual-inductor from overloading and circuit break. (Tested by National High-voltage Quality Supervising and Testing Center, in accordance with GB15166.2 and IEC282-1)

high voltage limit current fuse for protection of voltage transformer 1

◆Basic parameters

See chart for the fuse of basic parameters

Type

Rated Voltage (KV)

Rated current (A)

Rated brake current(KA)

Dimensions

XRNP1-□/□--1

7.2 (3.6) 12

0.2、0.3、0.5、1、2、3.15

50

See image 1

XRNP1-□/□-□-1

24

0.2、0.3、0.5、1、2、3.15

50

See image 2

XRNP1-□/□--2

12

2、3.15

50

See image 3

XRNP6-□/□--1

40.5

0.2、0.3、0.5、1、2、3.15

31.5

See image 4 (Φ25)

XRNP6-□/□-□-3

0.2、0.3、0.5、1、2、3.15、4、5

See image 5 (Φ30)

XRNP6-□/□--4

0.2、0.5、1、2、3.15、5、6.3

See image 6 (Φ41)

Note: Among them, 7.2KV, 12KV (Φ25 pipe diameter) have three non-standard wiring forms as shown in Figure 7.

high voltage limit current fuse for protection of voltage transformer 2 high voltage limit current fuse for protection of voltage transformer 3 high voltage limit current fuse for protection of voltage transformer 4 high voltage limit current fuse for protection of voltage transformer 5 high voltage limit current fuse for protection of voltage transformer 6 high voltage limit current fuse for protection of voltage transformer 7 high voltage limit current fuse for protection of voltage transformer 8 high voltage limit current fuse for protection of voltage transformer 9

> Hot Products

News Center

> How to choose a fuse

In order to better protect circuits and products, the choice of fuse is very important. The fol...

> Protection characteristics of fuse

The protection characteristic of the fuse can also be called melting characteristic, which is t...

> Installation requirements of the fuse

The installation requirements of the fuse melt, and some precautions when installing the fuse.

> Analysis and Maintenance of Common Faults of Fuse

When the melt is blown out, please carefully analyze the causes and possible causes of the fuse

> The difference between a fuse and a circuit breaker

Circuit breakers are commonly used components for low-voltage power distribution. It is also su...

> Precautions and maintenance of fuses

In the application, attention should be paid to the use of fuse precautions, daily inspections ...

> Precautions for fuse

In the application, attention should be paid to the use of fuse precautions, daily inspections ...

> Use and maintenance of fuses

The fuse has the advantages of simple structure, convenient use, low price, etc., and is widely...